Designing an RE wall / RS wall? Seven things every design must cover

A sound reinforced soil wall design starts with the right material properties, loads and water conditions, then checks stability, serviceability, facing and drainage.

Panel-faced reinforced soil wall at a flyover approach

Reinforced soil (RS) walls, also known as RE walls (a trademark of the Reinforced Earth Company) or MSE walls, now carry most flyover approaches, road over bridges and expressway embankments in India. They are fast to build and cost less than concrete retaining walls.

Many people think RS wall design is a set of stability calculations. Those calculations are only as good as what goes into them. A sound design starts with the right material properties, loads and water conditions, then checks stability, serviceability, facing and drainage. These are the seven things we cover on every RS wall at C-Phi Consult.

1. Material properties

Every calculation depends on three sets of material data:

  • Reinforcement: geogrid, geostrip and metallic reinforcement properties vary from manufacturer to manufacturer. The design must use the long-term design strength of the actual product, after reduction for creep, installation damage and durability, not the strength printed on a product sheet.
  • Backfill and retained soil: grading, friction angle, unit weight and drainage of the reinforced fill, and the properties of the soil retained behind it.
  • Foundation soil: strength, compressibility and groundwater level of the ground the wall stands on, from a proper soil investigation.

If the site later changes the reinforcement product or the fill source, the design must be checked again.

2. Loading and water conditions

  • Dead load from the fill, pavement and any structure on top
  • Live load from traffic, and surcharge during construction
  • Water conditions: dry, saturated, water-logged, or flowing water and scour beside rivers and canals
  • Seismic loading for the wall's seismic zone
  • Special loads such as crash barriers, sign gantries, bridge abutment loads or nearby foundations

Water is the condition most often underestimated, and the one behind many distressed walls.

3. External stability, static and seismic

The reinforced block is checked as one mass for:

  • Bearing capacity of the foundation soil
  • Sliding on the base
  • Eccentricity, so the resultant stays within the allowed part of the base
  • Global stability, where a deep slip surface passes under or through the whole wall, including compound failure through the reinforced zone

Each check is made for both static and seismic cases. Where the foundation is weak, we design ground improvement or basal reinforcement.

4. Internal stability, static and seismic

Each reinforcement layer is checked for:

  • Rupture: the layer must carry its share of earth pressure without breaking
  • Pull-out: it must be anchored far enough behind the failure zone that it cannot slide out
  • Sliding along the reinforcement layers within the fill

5. Serviceability: deformation and settlement

A wall can be stable and still fail its purpose if it moves too much. We check wall face deformation and total and differential settlement, especially where the wall meets a bridge abutment or another structure.

6. Facing design and connections

The facing must be designed, not just specified:

  • Precast panels: panel reinforcement design and connection details to the reinforcement
  • Modular blocks: block-to-geogrid connection strength
  • Gabions: gabion-to-geogrid connection, with or without a reinforcement bar

7. Drainage for the site's conditions

Drainage is designed for the water conditions in point 2: drainage layers behind the facing, filters to stop fines washing out, weep holes and outlets, and protection against surface water and scour.

Design standards we follow

  • IRC SP 102:2014
  • IS 18591:2024
  • BS 8006-1 (2016 amendment)
  • FHWA guidelines for mechanically stabilised earth walls and reinforced soil slopes

Analysis is carried out using our in-house software, C-Phi RS Wall and C-Phi Slope2D, along with MSEW, ReSSA, GEO5 and Plaxis.

Get a second opinion before you build

We also proof check RS wall designs prepared by others, value engineer tender designs, and carry out forensic reviews of distressed walls. Send us the alignment, wall heights and any soil data you have, and we'll reply with an approach and a fee.